How to adjust the floor heating if it is too hot? Analysis and practical guide of hot topics across the Internet in 10 days
Recently, as the temperature drops sharply in winter, the use of floor heating has become a hot topic on the Internet. Many users have reported that the floor heating temperature in their homes is too high, causing dryness and discomfort. This article will combine the hot topic data of the past 10 days to provide you with structured solutions.
1. Statistics of hot topics related to floor heating on the entire network (last 10 days)

| Ranking | Topic keywords | Number of discussions (10,000) | Main questions |
|---|---|---|---|
| 1 | Floor heating is too dry | 12.5 | Indoor humidity is less than 30% |
| 2 | Floor heating temperature adjustment | 9.8 | Improper operation of water diverter valve |
| 3 | Floor heating consumes high energy | 7.3 | The set temperature exceeds 22℃ |
2. Analysis of the 5 major reasons why the floor heating temperature is too high
1.Water temperature set too high: The default temperature of the boiler is usually set at 60-70℃, but the actual temperature is only 45-55℃.
2.Water distributor is not adjusted in groups: The bedroom/living room should have independent temperature control to avoid overall overheating.
3.Thermostat failure: 10% of users reported that the thermostat display was abnormal and the battery needed to be replaced or calibrated.
4.Ground cover too thick: Carpets and floor mats can hinder heat dissipation and cause heat accumulation.
5.System first run: There may be temporary overheating 3 days before newly installed floor heating.
3. Step-by-step adjustment guide (with parameter recommendations)
| steps | Operation content | Recommended parameters |
|---|---|---|
| first step | Check boiler outlet water temperature | Adjust to below 50℃ |
| Step 2 | Adjust the manifold valve | The bedroom is 1/2 open and the living room is 2/3 open |
| Step 3 | Set up the thermostat | 18-20℃ (can drop to 16℃ at night) |
4. Three effective cooling techniques tested by netizens
1.time switch method: Turn off the floor heating in the bedroom from 8 a.m. to 6 p.m. and use the residual heat to maintain comfort.
2.Windows slightly open for convection: Open the window with a 5cm gap and ventilate twice an hour (antifreeze is required in the north).
3.humidifier assist: Xiaomi Humidifier Pro (2023 model) can increase humidity by 15%-20%.
5. Professional advice: adjustment plans for different house types
| House type | Recommended water temperature | Daily running time |
|---|---|---|
| New commercial building (good insulation) | 45℃ | 8-10 hours |
| Old brick-concrete structure | 50℃ | 12 hours |
| Villa/duplex | hierarchical control | The first floor is always open, the second floor is open regularly. |
6. Precautions
1. After adjustment, you need to wait 2-3 hours to observe the effect. The floor heating system is thermally inert.
2. In extreme cases, the 1-2 way water diverting valve can be closed (such as study room, storage room).
3. If self-adjustment is ineffective, it is recommended to contact professionals for system hydraulic balance debugging.
Through the above methods, 90% of overheating problems can be improved. According to 12,000 discussion data on the topic #floor heating temperature control on Zhihu, an average monthly gas bill of 15%-20% can be saved after reasonable adjustments.
check the details
check the details